Setting up Einstein on 2nd computer.

Anonymous
Topic 13040

The key message is "Master file fetch failed". The client couldn't make any contact with our server. Check the internet settings of that machine, especially proxies. Try to open a browser on that machine with the einstein URL.

BM

Bernd Machenschalk
Bernd Machenschalk
Joined: 15 Oct 04
Posts: 2,684
Credit: 25,950,161
RAC: 34,820

Setting up Einstein on 2nd computer.

The port 31416 was used for communication between the client and the GUI / Manager before BOINC was officially given the privileged port 1043. In case that you are using an older client (such as 4.19) with a newer Manage, then you need the port 31416, otherwise the 1043 will be used.

In any case all communication between the Client and the outside world (i.e. the server) is made via the usual http port 80.

BM

BM